H2 Analyzer HY-OPTIMA 2700

Explosion Proof In-line Hydrogen Process Analyzer H2scan’s HY-OPTIMA® 2700 series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA® 2700 series is an explosion proof device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 60ºC. The HY-OPTIMA® 2700 series is ideal for process gas applications where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.

  • Verification Interval: 90 days

  • Product Life Expectancy: 10 Years

  • Pressure Compensation: Yes

  • Operating Humidity: < 95% RH (non condensing)

  • Flow Rate: 0.1 to 10 slpm

  • Process Gas Temperature: -20°C to 60°C

  • Operating Temperature-20°C to 55°C

  • Storage Temperature -30°C to 80°C

  • Output Signals

  • Analog: 4 to 20mA (or user specific mA)

  • Serial: RS422 or TS422

  • Relay Contacts²: 5A/240 VAC or 5A/30 VDC

  • Input Voltage: 90-240 VAC

  • Input Power: 15W

  • Dimensions: 7.5in (L) x 5.4in (W) x 5.7in (D)

Adapter Fitting: 3/4 in Union Tee Compression

1. ATEX versions are limited to 1.1 ATM max process gas pressure

2. Two programmable relays and one fault relay with normally open (N.O.) and normally closed (N.C.) contacts


Feature

The HY-OPTIMA™ 2700 Series inline hydrogen process analyzer is ideal for gas streams where real-time, 

hydrogen-specific measurements can enhance process plant efficiencies, improve yields, and reduce maintenance costs:


Refinery

•Catalytic reforming

•Hydrodesulphurization

•Fuel gas

•Tail gas treating units


Natural Gas

•H2 measurement in polymer feeds and flare gas process streams


Manufacturing

•Metals annealing

•Semiconductors

•Oil hydrogenation




Performance                                                             



Operating   Pressure at Analyzer:

Recommended:

0.95 1.1 atm absolute (14.0 16.1 psia)

Maximum:

2 atm absolute   (29.4 psia)

Note:   Analyzers are factory calibrated at 1 atm.   For operation at higher pressure special factory calibration is required   which may incur a nominal

fee.

Process Gas   Temperature:

-20 to 60°C

Flow Rate:


0.1 to 10 slpm

Operating Humidity:

< 95% RH (non-

condensing)

Calibration   Interval:

90 days

Output Signals                                                                                  

Analog: 4-20 mA


Serial: RS232 or   RS422

Relays: 5A/240   VAC or 5A/30 VDC

Two programmable   relays and one fault relay

Power                                                                          



Input Voltage


Input Power

90 240 VAC, 50 60 Hz

15 W

Physical                                                                     



Dimensions


Weight

7.5in (L) x   5.4in (W) x 5.7in(D)

5.9 lbs

Adapter Fitting:   ¾ Inch Union Compression Tee

Environmental                                                                                  

Operating temp:   -20 to 55°C

Storage temp:   -30 to 80°C

Ingress   Protection: IP67